Report: Essential Guide: CVE-2026-33701 - OpenTelemetry: Unsafe Deserialization in RMI Instrumentation may Lead to Remote ...
CVE ID :CVE-2026-33701 Published : March 27, 2026, 1:16 a.m. | 15 minutes ago Description :OpenTelemetry Java Instrumentation provides OpenTelemetry auto-instrumentation and instrumentation libraries for Java. In versions prior to 2.26.1, the RMI instrumentation registered a custom endpoint that deserialized incoming data without applying serialization filters. On JDK version 16 and earlier, an attacker with network access to a JMX or RMI port on an instrumented JVM could exploit this to potentially achieve remote code execution. All three of the following conditions must be true to exploit this vulnerability: First, OpenTelemetry Java instrumentation is attached as a Java agent (`-javaagent`) on Java 16 or earlier. Second, JMX/RMI port has been explicitly configured via `-Dcom.sun.management.jmxremote.port` and is network-reachable. Third, gadget-chain-compatible library is present on the classpath. This results in arbitrary remote code execution with the privileges of the user running the instrumented JVM. For JDK >= 17, no action is required, but upgrading is strongly encouraged. For JDK < 17, upgrade to version 2.26.1 or later. As a workaround, set the system property `-Dotel.instrumentation.rmi.enabled=false` to disable the RMI integration. Severity: 9.3 | CRITICAL Visit the link for more details, such as CVSS details, affected products, timeline, and more...